FREE FINANCIAL EDUCATION
TPO POC tie-breaking sensitivity
Apply a maximum-count, midpoint-distance, lower-row tie hierarchy.
What you will learn
Prerequisites: TPO maxima, profile midpoint and deterministic tie rules.
- Apply a maximum-count, midpoint-distance, lower-row tie hierarchy.
- Identify how a low-count extreme can affect a midpoint-based tie.
- Report tied regions instead of claiming unjustified point precision.
Mechanism and decision rules
A TPO profile can have several rows with equal maximum counts. A deterministic implementation must select one or report a tie. One documented convention chooses the tied row closest to the midpoint of the profile’s price range, then the lower row if distance also ties. This lesson uses that hierarchy explicitly; other conventions should be labeled rather than assumed wrong.
Tie-breaking is a display or analytical convention, not additional evidence that the selected row contains more participation. A small extension at an extreme can move the range midpoint and change the selected POC even if all tied row counts stay unchanged. Report the tied region and neighboring counts when the exact chosen price is sensitive to this rule.
Worked example · synthetic data
Synthetic rows 100,102 and 104 each have five TPOs, and the profile range is 100–104. Midpoint is 102, so the hierarchy selects 102. Now one new TPO appears at 110. The three maximum rows still tie at five, but the range midpoint becomes 105. Distances are 5,3 and 1, so the selected POC becomes 104.
No extra TPO was added to 104. The selected level changed because a low-count extreme changed the midpoint used to resolve the tie. Treating that shift as a strong migration signal would overstate what happened.
Failure modes and limits
Profile midpoint can mean different things in different software; verify whether it uses price-range midpoint or another definition. Row labels and tick rounding matter. A tie-sensitive POC should not be presented as a uniquely dominant auction price. Later corrections can alter both extremes and counts.
Practice case
Rows 200 and 204 tie at the maximum and the full range is 200–204. Under midpoint proximity then lower-row preference, which POC is selected? What if a new one-count row appears at 208 without changing the tie counts?
Reveal the worked answer
Initially midpoint 202 leaves both maxima two units away, so 200 is selected by the lower-row rule. With the range extended to 208, midpoint 204 selects 204 directly. The leading counts did not change; the tie-break reference did.
Check your understanding
Sources and next steps
The lesson, calculations and synthetic cases are original educational material. References explain underlying contract or chart conventions; none validates the profitability of a trading rule. Actual contract specifications, settlement obligations and charges must be checked before trading.
Explore OHLCV data in the chart lab · Explore volume-at-price and TPO data · Practice library
